Let’s cut to the chase: if you’re deep in the high-speed SerDes game, you’ve definitely heard people bang on about “BER” like it’s the holy grail of performance. But here’s the thing—most folks don’t actually know what a good BER is, especially when you’re pushing 100G+ links, backplanes, or transceivers that need to work reliably 24/7, no room for glitches. As a SerDes supplier that’s been designing, testing, and shipping these bad boys for nearly a decade, I’ve sat through more late-night debugging sessions with system engineers than I can count, and one question comes up every single time: “What BER do I actually need, not just what’s on a spec sheet?” High-speed SerDes

First, let’s get one myth out of the way: BER isn’t a universal number. It’s not like 1e-12 is the end-all-be-all for every use case, and if someone tells you their SerDes has a “perfect” 0 BER, run. Zero BER only exists in simulations and lab fairy tales. In the real world, every SerDes link—from a short cable between a switch and server to a 30-inch backplane running to a router line card—has some bit errors. The trick is knowing what level of errors is so low that they’re invisible to your system, your end users, and won’t cost you a dime in downtime, reboots, or angry support calls.
Let’s break down what BER actually means for anyone who doesn’t geek out over signal integrity math on their lunch break. BER stands for Bit Error Rate, and it’s the ratio of bits that get flipped (1 becomes 0, 0 becomes 1) during transmission to the total number of bits sent over a link. A 1e-6 BER, for example, is 1 error every 1 million bits. A 1e-12 BER is 1 error every 1 trillion bits. That difference might sound trivial, but when you’re moving terabits per second, it adds up fast.
Here’s where my perspective as a SerDes supplier comes in: most of our customers don’t need the lowest possible BER—they need the right BER for their specific application. Let’s walk through the most common use cases we deal with, because that’s where the rubber meets the road.
Take data center servers, for example. We supply SerDes for 400G and 800G Ethernet links between server CPUs, NICs, and top-of-rack switches. These links run 24/7, and even a tiny spike in errors can cause packet retransmissions. Wait—packet retransmissions! That’s the big secret no one talks about. For Ethernet, a single bit error triggers a full packet retransmit, not just fixing that one bit. So if you have a 1e-10 BER at 800G, that’s roughly 80 errors per second. Each error means retransmitting a full 1500-byte packet, which is 12,000 bits. Suddenly, that 80 errors a second turns into 96,000 packet retransmits a second—that’s a huge waste of bandwidth, and it’s why most cloud hyperscalers we work with spec a net BER of less than 1e-12. Wait, “net” is key here too—because SerDes chips have built-in FEC (Forward Error Correction), right? FEC fixes a certain number of errors without the system even knowing. So the pre-FEC BER (before FEC kicks in) can be higher, like 1e-5 to 1e-6, and FEC will drop that to a post-FEC BER of 1e-12 or lower. That’s a huge cost saver for customers, because higher pre-FEC BER means less power, smaller chips, and lower cost—if your FEC is good enough.
Another common use case: telecom core network backplanes. These links are carrying voice, video, and data that need near-zero latency and zero downtime. If you’re streaming 4K or 8K video, a single packet retransmit can cause a freeze or a glitch, and for telecom, downtime is literally a regulatory and revenue killer. For these applications, we’ll often work with customers to target a post-FEC BER of less than 1e-15. That’s way lower than data center needs, and the reason is simple: a 1e-15 BER is 1 error every 1 quadrillion bits, which is basically undetectable in real-world operation. The tradeoff here is that telecom SerDes might use slightly more power or a more advanced FEC, but for them, that’s worth it for reliability.
Now, what about shorter-reach links, like for on-board SerDes in base stations or edge compute boxes? These are shorter, so signal loss is less, and they don’t have the same strict latency requirements as core networks. We often see customers here targeting a post-FEC BER of 1e-10, which is totally acceptable. Why? Because the link is only a few inches long, errors are rare, and FEC can fix the remaining ones. This is where I see a lot of engineers overspending unnecessarily—they’re specifying a 1e-12 BER for a short edge link that doesn’t need it, just because they think “lower is better.” Spoiler: that extra 2% power draw or $0.50 per chip premium adds up to millions over a 10,000-unit order, and for what? No real benefit.
Wait, let’s talk about what happens if you get the BER wrong. Too high, and you get errors that FEC can’t fix, leading to uncorrectable errors (UEs) that crash links, cause reboots, or break applications. Too low, and you’re wasting money and power for no reason. I once had a customer come to us a year ago who had a SerDes from another supplier that was specified for 1e-12 BER, but it was only delivering 1e-8 post-FEC on their 100G backplane. They were seeing random server crashes every few days, and their team was going crazy debugging software, thinking it was an OS issue, when it was just uncorrected bit errors. We swapped in our SerDes, optimized for their backplane’s specific loss (we do custom equalization tuning for every customer, by the way), and got them to 1e-13 BER without increasing power. Their crashes went away immediately. That’s the kind of problem we solve every day.
Another point: FEC isn’t one-size-fits-all. Different FEC codes have different correction capabilities, speed, and power tradeoffs. For example, Reed-Solomon FEC is older, works well for low speeds, but consumes more bandwidth for high-speed links. LDPC (Low-Density Parity-Check) FEC is newer, more efficient for high speeds, can fix more errors with less overhead. As a SerDes supplier, we tune our FEC IP to match each customer’s use case, because that’s how you get the best BER without overdesigning. A lot of competitors will sell you a SerDes with a generic FEC that’s overkill for your application, pushing up your cost. We work with customers to find the exact FEC and BER balance that fits their needs.
Let’s also address a common misconception: some people will say, “BER doesn’t matter because we use retransmissions.” That’s true for TCP links, but for low-latency applications like 5G RAN (Radio Access Network) fronthauls, TCP retransmissions are way too slow. 5G requires sub-1ms latency, so retransmissions aren’t an option—you need errors fixed at the physical layer, which means a strict BER spec of 1e-12 or lower post-FEC. That’s why all the major 5G vendors we supply to specify that exact number. For TCP-based data center traffic, retransmissions work, but they kill bandwidth efficiency—so why waste that bandwidth when you can get a lower BER with a slightly optimized SerDes?
So, circling back to the original question: what is a good BER for high-speed SerDes? The short answer is: it depends on your use case, your link length, your FEC capability, and your tolerance for errors. But to give you concrete numbers based on what we see our customers actually use:
- Data center core (400G/800G Ethernet, inter-server): Post-FEC BER ≤ 1e-12
- Telecom core backplanes, 5G fronthauls: Post-FEC BER ≤ 1e-15
- Edge compute, short-reach on-board links (100G/200G): Post-FEC BER ≤ 1e-10
- Test and lab links: Pre-FEC BER up to 1e-3 is totally acceptable, since FEC isn’t in use
Wait, let’s make one thing clear: pre-FEC BER is not the same as the “real” BER. No system cares about pre-FEC errors, because FEC fixes them. The only number that matters is post-FEC BER. A lot of sneaky suppliers will quote pre-FEC BER specs that look impressive, but don’t translate to real-world performance once FEC is applied. That’s why we always provide post-FEC BER numbers in our datasheets, and we give each customer a custom link margin analysis based on their specific design, so they know exactly what BER they’ll get in their actual system, not just in our lab.
I should also mention link margin, because that’s what directly impacts BER. Link margin is the difference between the signal power at the receiver and the receiver’s sensitivity threshold. The higher the margin, the lower the BER. A lot of engineers will calculate link margin during design, but they don’t account for real-world factors like temperature, voltage variations, or component aging. We test our SerDes over full industrial temperature ranges (-40°C to 85°C) and across voltage corners, so we can guarantee that the BER stays within spec even when the system is operating in harsh conditions. If you buy a SerDes that only meets its BER spec at 25°C, you’ll start seeing errors once your equipment heats up in a data center or a telco cabinet. That’s a problem we don’t let our customers face.
Now, if you’re out there designing a new SerDes-based system and you’re still not sure what BER you need, or if you’re fed up with bad BER performance from your current supplier, let’s talk. We don’t do one-size-fits-all specs. We’ll work with your team to analyze your link, your use case, your budget, and your performance requirements, and give you a custom SerDes solution that hits exactly the BER you need—no overpaying, no underperforming. We’ve worked with startups building edge AI boxes, hyperscalers rolling out 800G networks, and telecom giants upgrading their 5G core, so we’ve seen just about every use case, and we’re happy to help you avoid the mistakes we’ve seen others make.

At the end of the day, a “good” BER isn’t the smallest number on a page. It’s the number that keeps your system running reliably, doesn’t waste your bandwidth or power, and fits your budget. As a SerDes supplier, that’s what we deliver—no fancy marketing, no empty specs, just real performance that works in the real world. If you’re ready to stop guessing about BER and get a solution tailored to your needs, reach out and let’s chat. We’ll even send you a free link margin analysis for your design, no strings attached.
Switches and Multiplexers References:
- IEEE 802.3bs-2017: Standard for Ethernet Amendment 10: Media Access Control Parameters, Physical Layers, and Management Parameters for 200 Gb/s and 400 Gb/s Operation
- ITU-T G.826: End-to-end performance parameters and objectives for international constant bit rate digital paths at or above the primary rate
- Cisco White Paper: SerDes Performance for High-Speed Data Center Interconnects, 2022
- IEEE 802.11ax-2021: Standard for Information technology—Telecommunications and information exchange between systems Local and metropolitan area networks—Specific requirements Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications Amendment 1: Enhancements for High Efficiency WLAN